Chemistry
Mindray
ASTM E1394 · RS-232 / TCP/IP
Bidirectional ordering

Connect Your Mindray BS-430 to Any HIS or LIMS

The Mindray BS-430 is a fully automated clinical chemistry analyser covering liver, kidney, lipid, and metabolic panels, common in mid-size hospital labs.

Connect the BS-430 to your LIS in both directions. LISBridge parses BS-430 chemistry results (framed and unframed ASTM variants) and dispatches test orders from your LIS to the analyser as an ASTM worklist download — one of 16 order-capable instruments. The BS-430 can also pull its own worklist: when it sends a host query asking what to run for a sample, LISBridge answers with the pending order, or an explicit no-order reply if there is nothing waiting.

< 30 min
Setup time
ASTM E1394
Protocol
RS-232 / TCP/IP
Connection
>99.9%
Parse accuracy

How LISBridge Connects the Mindray BS-430

01

Connect your instrument

Plug in via RS-232 or point it at LISBridge over TCP/IP. Auto-detection identifies the instrument and loads the correct parser — no manual selection.

02

Parse the data

LISBridge reads the ASTM E1394 stream in real time. Every result message is decoded — field by field — into structured data.

03

Validate results

Each result is checked for completeness. Duplicates caught. Malformed messages flagged. Only clean data moves forward.

04

HIS receives clean data

Validated results reach your HIS automatically — as HL7 or direct format. Stored locally too. No manual entry required.

Mindray BS-430 — Frequently Asked Questions

Does the Mindray BS-430 support host query?

Yes. The BS-430 can ask LISBridge what tests to run for a sample rather than waiting to be sent a worklist. LISBridge answers the query with the pending order for that specimen, and replies explicitly when there is no order — so the analyser is never left waiting on silence.

What protocol does the Mindray BS-430 use?

The BS-430 uses ASTM E1394. LISBridge handles both the framed (ASTM v2) and unframed variants the BS-430 can produce, including reading the specimen barcode from the order record.

Does LISBridge support bidirectional ordering on the BS-430?

Yes. Orders created in your LIS are transmitted to the BS-430 as an ASTM worklist download, and results flow back automatically — no keypad entry at the instrument.

What chemistry tests does LISBridge extract from the BS-430?

Every test code the analyser reports — ALT, AST, ALP, GGT, bilirubin, creatinine, urea, glucose, lipid panel, proteins, electrolytes, and any other tests configured on your BS-430.

How long does BS-430 setup take?

Under 30 minutes. Connect via RS-232 or TCP/IP and LISBridge auto-detects the BS-430 from its message header — the dedicated parser loads automatically.

Connect your Mindray BS-430 today

Start your free 7-day trial — no credit card required. Full ASTM E1394 support from day one.